The coach

An electric bed with a unique and innovative design, with 4 electric motors for adjusting the height of the bed and the inclination of the seat, thereby providing both the customer and the operator with maximum comfort. EsthLab is an expression of style: its steel base, high-quality finish and innovative technology make it capable of adapting perfectly to any professional environment.

The facial and body technologies

Medilas_content_giuong-dien

RF Monopolar Procedure (Face arid body). Monopolar procedure is primarily used to treat skin laxity by triggering tightening and is best suited to patients with mild to moderate sagging of facial or body tissues, usually those in their mid thirties to fifties, with any skin colour.

It works by producing heat when the tissue's electrical resistance converts the electric current to thermal energy deeper within the dermis. The generated RF current flows through the body and grounding or return pad is needed. The initial collagen structural change, which is created within these thermally modified deep tissues, causes immediate tissue contraction and subsequent formation of collagen.

Face and Body Bipolar procedure

With bipolar delivery, the current from the RF generator flows only through the tissue area which is between the two electrodes on the handpiece’s tip, generating an arch of radiofrequency emission; these electrodes start and complete the electrical circuit. Hence, with bipolar delivery, no current flows through the rest of the body, so no grounding or return pad is needed.

CRF, Combined Cavitational and RF Monopolar Body Handpiece

Body CRF procedure alleviates cellulite symptoms and melts fat by means of several mechanisms: cellular and fibrosis disruption due to ultrasonic cavitation; dermal tightening of fibrous filaments due to thermal injury affecting the network of blood vessels, which triggers a cascade of inflammatory events, including fibroblast proliferation and apparent up-regulation of collagen formation; enhancement of local blood circulation (vasodilatation and hyperemia) and drainage of fatty deposits to the lymphatic system; fat cell disintegration and thermal-induced fat cell apoptosis.

Sub-dermal Massage using Vacuum (Face and Body RF Monopolar Handpieces)

Vacuum and specially designed suction cups for the Subdermal Massage smooth out the skin to facilitate safe and efficient RF heat energy delivery. The sub- dermal massage increases the metabolism of stored energy and increases lymphatic drainage.

LipoShock procedure

The cells in our body react to heat or cold at different temperature levels. During the “LipoShock" procedure, the sophisticated device's applicator is pressed against the area to be treated thanks to the contemporary action of vacuum aspiration and support of an elastic band. A sequential process of intense heat (60°) and intense cold (-10°) is able to target only the fat cells in that area. After the procedure the fat cells begin a process called “apoptosis", which brings them to a natural physiological death. At this stage the body reacts with an inflammatory response that causes the natural dispose of the damaged fat cells. The procedure allows a significant improvement in the shape of the treated area.

Pressoteraphy procedure

Pressotherapy is an exclusive detoxifying treatment, which through effective lymphatic drainage, helps to promote the body's natural toxin clearing functions. The revitalization and oxygenation of the tissue helps to slim and redefine the legs, stomach and arms while enhancing skin tone.

. Recommended for the treatment of cellulite

. Slimming and detoxifying. Following liposuction

. Body shaping and profiling

. Relieves pain and swelling, and provides immediate comfort

. Redefines the legs, stomach and arms while enhancing skin ton

Skin and muscles toning procedure

The unique skin and muscles toning procedure utilizes sequential currents phases that reproduce the natural stimulation of muscles body function with a continuously changing pattern of pulse widths, frequencies, timings and intensities to provide the most effective treatment for body and face shaping requirements. In order to imitate this natural type of neurological activity, the technology has introduced microprocessor controlled programmes which automatically vary, cycling through many different settings in each Programme. As in normal exercise, a warmup and a warmdown mode is incorporated to ensure total relaxation after each session.

Abralase procedure

Abralase features the precision of a hand- piece projecting a flow of fine aluminum crystals, which works in synergy with a 630nm diode laser. Small {100-micron) particles of aluminum oxide are mixed into the airflow, and they are then delivered to the surface of the skin. After the particles stream across the skin surface, they are sucked back up into the machine along with the cellular debris. Abralase's procedure smoothes the most superficial layers of the skin, while the diode laser penetrates into the tissue, where it is absorbed by the cells and converted into energy that can accelerate metabolic processes. The operator can control the intensity of the abrasion, starting from a light exfoliation of the skin, progressively increasing up to a deep exfoliation in specific

MesoSkin procedure

The MesoSkin procedure features electroporation that uses the properties of high-intensity pulse to ensure a deep, subcutaneous penetration of skin formulations and active ingredients sensitive to electroconduction, such as Neohair, to promote the growth and vitality of hair bulbs; Neoage, for skin rejuvenation; Neotone, for tissues' enhanced tone; and Neocell, to fight the imperfections caused by cellulite and localized fatty areas.

The Laser and Light Technologies

. Calibrated Pulsed Light (broad spectrum) procedure

Superior by design, the new Calibrated Pulsed Light (CPL) Applicator offers several innovative and advanced technology enhancements. Compared to the other IPL systems available on the market, the system has proven to be among the most powerful. The Calibrated Pulsed Light Applicator is simple and efficient to operate; controls are within easy reach and important user information is clearly displayed on the color monitor, including energy delivered and treatment setting with true energy fluence up to 30 J/cm2.

. Nd:YAG (infrared 1064 nm) procedure

The Nd:YAG Applicator allows fast and effective laser hair removal treatments in the darkest skin types. The calibrated laser beam ensures light penetration to the deepest follicles while its low absorption guarantees preservation of the surrounding tissues on all skin types. The zoom handpieces allow an accurate selection of the hair reduction treatment area size and instantly switch to more focused laser spots for fine vascular treatments.

. Alexandrite (755nm)

The Alexandrite Applicator provides a more effective melanin absorption, as compared to other similar wavelengths, including diode lasers. The absorption of the laser energy by the melanin in the skin creates a better transfer of energy and more effective destruction of the hair follicles with consequential permanent hair removal. The Alexandrite applicator is superior to other systems when removing fine, thin hairs.

. Q-switched Nd:YAG (1079/539nm)

The Q-switched Nd:YAG Applicator is the ideal choice for the treatment of pigmented lesions, such as sun-damaged skin and age spots, and for the removal of unwanted tattoos. Nd:YAG 1079 nm: ideal for treating dark tattoos, dermal pigmented lesions, and for skin resurfacing. Nd:YAG/KTP 1079/539 nm: optimal for bright colored tattoos and solar lentigines, it is also used for vascular lesions, including facial and leg veins, telangiecta- sias, and angiomas.

. Erbium YAG (2940nm)

The Erbium YAG Applicator is able to remove microscopic layers of skin, producing outstanding results with minimal risk and adverse reactions. The laser can remove both superficial and medium depth lines, including some scarring, depending on the controlled depth of the ablation and the amount of treatments performed. The Erbium YAG Fractional procedure produces thousands of deep, tiny columns in the skin. It works on old epidermal pigmented cells without affecting the surrounding tissue, thus reducing healing time (about 24 hours) and promoting the skin's natural regenerating process. It is a safe, non-invasive procedure that allows fresh, healthy and young skin.

. Diode (infrared 810 nm)

The laser DYT Diode handpiece provides permanent hair reduction using cutting edge high-power diode technology. It guarantees rapid and non- invasive procedure without downtime and on all skin types (l-VI), as well as tanned skin and pseudofolliculitis barbae.

Related posts